High quality china do dissolved oxygen meter/controller price for drinking water treatment equipment

                            High quality china do dissolved oxygen meter/controller price for drinking water treatment equipment

                            High quality china do dissolved oxygen meter/controller price for drinking water treatment equipment

                            High quality china do dissolved oxygen meter/controller price for drinking water treatment equipment

                            High quality china do dissolved oxygen meter/controller price for drinking water treatment equipment

High quality china do dissolved oxygen meter/controller price for drinking water treatment equipment

High quality china do dissolved oxygen meter/controller price for drinking water treatment equipment,Sinomeasure,Machinery & Industrial Parts,Measurement & Analysis Instruments,Analyzers,Other Analysis Instruments
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Place of Origin:
Zhejiang, China (Mainland)
Brand Name:
Sinomeasure
Model Number:
SIN-DO200-33ff
Product name:
Dissolved Oxygen Meter
Application:
Water Treatment Industry
Measurement range:
0-20 mg/L,0-20 ppm;
Power supply:
AC:100-240VAC DC:9~36VDC
Weight:
3.2kg
Accuracy:
±3% of the measured value
Usage:
Water Content
Resolution:
0.01mg/L
Detector Optional:
Dissolved Oxygen + Temp
Name:
online Dissolved Oxygen Meter
Packaging & Delivery
Packaging Details
Standard Package
Delivery Time
7 working days after the payment received
 High quality china do dissolved oxygen meter/co<em></em>ntroller price for drinking water treatment equipment
Models
SIN-DO9100
SIN-DO9100RS
SIN-DO9100D
SIN-DO9100DRS
Tested units
% / ppm / mg/l / TEMP.
 
 
Range
%
0~600 %(According to the electrode)
mg/l
0~60.00 mg/l(According to the electrode)
ppm
0~60.00 ppm(According to the electrode)
TEMP
0~100C(According to the electrode)
 
 
Resolution
%
0.1 %
mg/l
0.01 mg/l / 0.001 mg/l
ppm
0.01 ppm / 0.001ppm
TEMP
0.1C
 
 
Accuracy
%
±0.5% of reading ±1Digit
mg/l
±0.5% of reading ±1Digit
ppm
±0.5% of reading ±1Digit
TEMP
0.2C 1Digit with temperature correction
Temperature compensation
0~50C NTC30K/NTC22K automation compensation
0~50C manual temperature compensation
Salinity compensation
0.0~45.0 ppt manual compensation
Pressure compensation
Compensation range:0.500~2.500bar or 7.25~36.25psi manual adjustment
Calibration mode
Single point or two points calibrations
Working environment temperature
0~50C
Storage environment temperature
-10~70C
Display
Large backlight LCD display, automatic and manual backlight sensor selection
Models
SIN-DO9100
SIN-DO9100RS
SIN-DO9100D
SIN-DO9100DRS
Output current 1
Isolation-programming 4~20mA corresponding Dissolved oxygen Measuring range, maximum load 500
Output current 2
Isolation programming 4~20mA corresponding the temperature range, Max. load 500
Isolation programming 4~20mA corresponding the temperature range, Max. load 500
Communication interface
MODBUS Protocol
MODBUS Protocol
Relay control
Contact output
RELAY ON/OFF ,240VAC 0.5A Max.
Setting
Set of two independent HI/LO Control point , Hysteresis setting
Cleaning setting
ON 0~9999 seconds / OFF 0~999.9 hours
Protection level
IP65
Power supply
100V~240VAC±10%,50/60Hz
20V~40VDC, Imax.=0.5A
Installation methods
Wall mounted/ Piped / Paneled
Meter size
144 mm  144 mm  115 mm (HWD)
Hole size
138 mm  138 mm (HW)
Weight
0.8Kg

Features:
*The sensor adopts new type of oxygen sensitive membrane,with NTC temperature compensated function,whose measurement result has good repeatability and stability.
*Won't produce oxygen consumption when measuring and no requirement of flow rate and stirring.
Breakthrough fluorescence technology,without membrane and the electrolyte and almost not need maintenance.
*Built-in self-diagnosis function to ensure the accuracy of data.
*Factory calibration,not need calibration for a year and can carry out field calibration.
*Digital sensor,high anti-jamming capacity and far transmission distance.
*Standard digital signal output,can achieve integration and networking with other equipment without controller.
*Plug-and-play sensor,quick and easy installation.

 

Applications:
*DO online monitoring of different technological processes such as regulating      reservoir,biochemical pool and effluent of sewage treatment plant.
*DO online monitoring of water plant,surface water,industrial process water and aquaculture and etc.

Measurement range
DO:0-20 mg/L,0-20 ppm;Temperature:0-45
Measurement Accuracy
DO:±3% of  the value;  Temperature:±0.5
Pressure range
≤0.3Mpa
Calibration
Air automated calibration,sample calibration
Main material
Body:SUS316L + PVC(fresh water), Titanium alloy(marine),Oring:fluorine rubber;Cable:PVC
Power supply
AC:100-240VAC (50/60HZ)   DC:9~36VDC
Output
2-way 4-20mA
Relay
Setting three-way relays,programmed response parameter and response value.
Communication protocol
MODBUS  RS485
Storage temperature
-15-65
Measuring temperature
0-45
Dimensions
Sensor:Dia55mm*L 342mm Transmitter:145*125*162mm(L*W*H)
Weight
Sensor:1.85KG;Transmitter:1.35KG
Protective rate
Sensor:IP68/NEMA6P;Transmitter:IP65/ NEMA4X
Cable length
Standard:10m, the maximum may be extended to 100m
 
 
 

Backplane Connection Descriptions:

Connection
Wiring instructions
A
Anodes, MINBO / WTW / METTLER The electrode signal line
K
Cathode, MINBO/ WTW / METTLER The electrode signal line
GND
Temperature signal line
T/P
Temperature signal line
CHK
membrane check Signal line ( Applies only to WTW TriOxmatic 700 series electrode)
DC±8V
DC voltage ± 8V Output connection
(1)4-20mA + end
The current output 1 connection + side, for an external recorder or PLC control.
4-20mA - end
The current output 1 connection - side, for an external recorder or PLC control.
 
(2)4-20mA + end / D+(B)
The current output 2 connection + Side, for an external recorder or PLC Control
( only applies to DO-9100); RS-485 the output of the D+(B) (Applies only to DO-9100RS ).
 
4-20mA - end / G
The current output 2 connection -  Side, for an external recorder or PLC Control 
( only applies to DO-9100); RS-485 the output of the ground (Applies only to DO-9100RS ). 
NC / D-(A):
N/A or RS-485 The output of the D-(A) (Applies only to DO-9100RS). 
REL1
HI , High limited control external relay connection
REL2
L0,LOW limited control external relay connection
WASH
External cleaning device relay connection
100-240AC
Supply terminals
 
 

Q: How long will you give me the reply?
A: we will contact you in 1 hours as soon as we can.

Q:Could I visit your factory?
A: Sincerely invite you to visit our factory

Q: Do you provide samples?
A: Yes,we have materials in stock to help you to get the samples as soon as we can.

Q: How about the quality of the managements ?
A: We have a complete quality control system , all of our products will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO,CE we could send the certification test of our company to you.

Q: What is your terms of payment ?
A: We could accept T/T, Paypal, WU ,Credit Assurance

Q: What is the warranty for your product ?
A: Warranty: 2 years, Lifetime maintenance